And this guideline you ll need a minimum of.
Irc 2012 attic ventilation requirements.
Unvented attic assemblies code notes 2009 irc 2012 irc adequate attic ventilation is a long standing requirement in building codes for moisture control.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Always have a balanced ventilation system.
Ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing the amount of attic ventilation.
Near ridge of the roof.
According to the national roofing contractors association nrca a power vent with an airflow rate of 1 0 cubic foot per minute per square foot of attic space measured at the attic floor is generally considered to be equivalent to a 1 150 ventilation ratio.
Based on your 1100 sq.
Space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8.
Overflow drains having the same size as the roof drains shall be installed with the inlet flow line located 2 inches 51 mm above the low point of the roof or overflow scuppers having three times the size of the roof drains and having a minimum opening height of 4 inches 102 mm shall be installed in the adjacent parapet walls with the inlet flow located 2 inches 51 mm above the low point of the roof served.
The minimum net area of ventilation openings shall not be less than 1 square foot 0 0929 m2 for each 150 square feet 14 m2 of under floor area.
One ventilation opening shall be within 3 feet 915 mm of each corner of the building.
The ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
Nrca guidelines regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.